Main Features:
High accuracy and reliability due to the double DSP control system
Low power consumption up to 94%
Cold start directly and smart operation for users.
Simple to install: Capability to install the UPS into any distribution system (neutral not required on rectifier input)
Capability of regulating the output voltage (to offset voltage drops down long cable runs)
Built-in automatic and manual battery test feature, battery deep discharge protection and temperature compensating charger
Back-feed protection: To avoid energy feeding back into the mains supply should a fault occur
Reliable, filtered, stabilized and regulated sine wave output (double conversion on-line technology )with filters for atmospheric
Disturbance suppression- high reliability, full microprocessor control with no-break static and manual bypasses, extremely high short-circuit
Current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation
Transformer on the inverter output- maximum reliability and power availability- high level diagnostics: Event log with messages, status,
Measurements and alarms - available from the built-in LCD in several languages
Summary:
Highest reliability and maximum performance for power sharing and redundancy. Must UPS power systems have been explicitly designed to meet the demands of today's industrial processes and special projects where reliability, availability and serviceability are equally as important as product quality and technical competence.
High accuracy and reliability due to the double DSP control system
Low power consumption up to 94%
Cold start directly and smart operation for users.
Simple to install: Capability to install the UPS into any distribution system (neutral not required on rectifier input)
Capability of regulating the output voltage (to offset voltage drops down long cable runs)
Built-in automatic and manual battery test feature, battery deep discharge protection and temperature compensating charger
Back-feed protection: To avoid energy feeding back into the mains supply should a fault occur
Reliable, filtered, stabilized and regulated sine wave output (double conversion on-line technology )with filters for atmospheric
Disturbance suppression- high reliability, full microprocessor control with no-break static and manual bypasses, extremely high short-circuit
Current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation
Transformer on the inverter output- maximum reliability and power availability- high level diagnostics: Event log with messages, status,
Measurements and alarms - available from the built-in LCD in several languages
Summary:
Highest reliability and maximum performance for power sharing and redundancy. Must UPS power systems have been explicitly designed to meet the demands of today's industrial processes and special projects where reliability, availability and serviceability are equally as important as product quality and technical competence.
MODEL | EH9115-10K | EH9115-20K | EH9115-30K | EH9115-40K | EH9115-60K | EH9115-80K | |
CAPACITY | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW | |
INPUT | |||||||
Voltage | 380/400/415 Vac± 20%, 3 Phase +N | ||||||
Input Frequency | 50/60 Hz ± 10% | ||||||
Power Factor | > =0.95 | ||||||
MAX RFI | EN50091-2 Class A. | ||||||
Input voltage protection | Electronic Input out of tolerant protection | ||||||
OUTPUT | |||||||
AC Voltage Regulation (Batt. Mode) | 380/400/415 Vac ± 1%, 3 Phase +N | ||||||
Voltage tolerant | (balanced load: +/- %1)(unbalanced: +/- %2)(full load: +/-%5) | ||||||
Voltage regulation time | After full load: 25 ms | ||||||
Frequency Range | 50Hz (60Hz special product) | ||||||
Frequency tolerant | (synchron: +/-%2) (free running: +/-%0, 2) | ||||||
Efficiency (100% load) | > 85% | > 90% | |||||
Harmonic Distortion | < =3% THD (Linear Load), < =5% THD(Non Linear Load) | ||||||
Transfer Time | AC to DC | Zero | |||||
Inverter to Bypass | 4 ms (Typical) | ||||||
Waveform (Batt. Mode) | Pure Sine Wave | ||||||
Crest faktor | 3: 1 | ||||||
BATTERY | |||||||
Battery Type & Numbers | Maintenance free lead-acid batteries / 12V x 32pcs | ||||||
charge current | 8A | ||||||
Battery Start | Yes, UPS can be started without AC source. | ||||||
Battery protection | Automatic circuit breaker | ||||||
Battery voltage protection | Electronic 3 level alarms | ||||||
OVERLOAD | |||||||
Overload protection | (> 130-%150 load : 60 seconds ) (> %150 load : 30 seconds) | ||||||
Short circuit protection | Electronic protection | ||||||
Output voltage protection | Electronic out of tolerant protection | ||||||
PHYSICAL | |||||||
Dimension, D X W X H (mm) | 600*620*1200 | 600*720*1500 | |||||
Net Weight (kgs) | 200 | 265 | 315 | 342 | 405 | 560 | |
OPERATING ENVIRONMENT | |||||||
Humidity | 0% - 90% (NonLCCondensing) | ||||||
Temperature | 0 - 40° C | ||||||
Overtemperature protection | Electronic protection | ||||||
Noise Level | < 58 dBA (At 1 M) | < 63 dBA (At 1 M) | |||||
Altitude | < 1000 M Above Sea Level | ||||||
LED, LCD, Buzzer | YES | ||||||
MANAGEMENT | |||||||
Remote Control | Dry contact, RS232 | ||||||
. All specifications mentioned above are subject to change without prior notice. |