True on-line double conversion technology with advanced microprocessor control
Wide input voltage range with high frequency technology
Zero transfer time
Protection against all type of power problems
Self test while start of the UPS
Site wiring fault warning
On-battery power-on function
Smart RS232 communication interface optional
Intelligent slot available
Sealed acid battery, free-maintenance battery
Wide input voltage range with high frequency technology
Zero transfer time
Protection against all type of power problems
Self test while start of the UPS
Site wiring fault warning
On-battery power-on function
Smart RS232 communication interface optional
Intelligent slot available
Sealed acid battery, free-maintenance battery
Model | HC1K | HC1K(S) | HC2K | HC2K(S) | HC3K | HC3K(S) |
CAPACITY | 1000 VA/800 W | 2000 VA/1600 W | 3000 VA/2400 W | |||
INPUT | ||||||
Phase | Single phase with ground | |||||
Voltage Range | 145~ 275VAC/110~300VAC | |||||
Frequency Range | 40 Hz ~ 70 Hz; 50/60Hz Autoadaptation | |||||
Power Factor | ≥0.99 | |||||
OUTPUT | ||||||
Voltage Range | 220*(1±1%)VAC | |||||
Frequency Range | Main Mode: (47 ~ 52.8Hz) 50Hz Battery Mode: 50 Hz ± 0.2 Hz or 60 Hz ± 0.3 Hz | |||||
(57 ~ 62.8Hz) 60Hz | ||||||
Synchronized Range | ||||||
Current Crest Ratio | 3:1 | |||||
Power Factor | 0.8 | |||||
Output Waveform | Pure Sine Wave | |||||
Outlet | IEC*4 | IEC*4 | IEC*3+Terminal | |||
TRANSFER TIME | ||||||
AC to DC | Zero | |||||
Inverter to Bypass | <4 ms (Typical) | |||||
INDICATORS | ||||||
LED Panel | Load/ Battery Capacity/ Main Mode/ Bypass Mode/ Fault | |||||
LCD Panel | Load/ Battery/ Input/ Output/Operation Mode | |||||
ENVIRONMENT | ||||||
Operating Environment | 0- 40°C | |||||
Humidity | 20-90 % (non-condensing) | |||||
Noise Level | < 60dB @ 1 Meter | |||||
Temperature | -25°C - 55°C(no battery) | |||||
OTHER | ||||||
Protection | Load<110%, Keeping working; 110%<Load ≤130%>1min; 130%<Load ≤150%> Immediately | |||||
Efficiency | Up to 90% | |||||
Battery Inbuilt | 2pcs*12V/7.2AH | 6pcs*12V/7.2AH | ||||
Battery DC Voltage | DC24V/36V | DC72V/96V | ||||
PHYSICAL | ||||||
Dimension D*W*H(mm) | 400 X145 X 220 | 460 X 192 X 348 | 460 X 192 X 348 | |||
Net Weight(kgs) | 10.75 | 7.5 | 27.5 | 15 | 28.5 | 16 |
MANAGEMENT | ||||||
Smart RS-232/USB | Supports Windows®98/2000/2003/XP/Vista/2008,Windows®7,Linux,and MAC | |||||
Optional SNMP | Power management from SNMP manager and web browser | |||||
* Product Specifications are subject to change without further notice. |